Current location : HOME >> Products >>  CLP-PVC waterproof membrane

CLP-3000 pvc waterproof membrane

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5

PVC Waterproofing Membrane

PVC waterproofing membrane is an excellent high-quality polymer waterproof sheet, made of PVC resin by adding plasticizer, anti-UV agent, anti-aging agent, and stabilizer and other processing aids through extrusion and molding. As the highly-recommended product by the Ministry of Construction, it is featured by high tensile strength, great elongation, good stability, small shrinkage, low-temperature performances, good resistance to weathering and root penetration, and long service life.







H ( homogeneous polyvinyl chloride plastic waterproofing sheets ) is the principal material used on exposed roof applications, in vacuum or mechanically attached systems. These roofing      systems are suitable for new build and refurbishment applications, flat and pitched roofs. It is reliable, and convenient for construction.



Specification

Roofing membrane PVC waterproof membrane for flat roof
Thickness: 1mm, 1.2mm, 1.8mm, 2.0mm, 2.5mm
Width: 2.05M,2.1M, 1M or customized
Length: 10M, 20M, 25M
Colors:White, Dark grey, Light grey, Black, Blue, Red, and Copper green.
Depending upon roof area, membrane material can also be produced in special customized colors.

Type : with UV resistance and without Uv resistance



Performance Indicators: Executive standard (GB12952-2012)


No.

Project

Index


H

L

P

G

GL


1

The resin thickness of middle base/ mm ≥

 ——

0.40


2

Pull N/cm                         ≥

 ——

  120

 250

  ——

  120


3

Elongation at break %                ≥

200

150

 ——

200

100


4.

tensilestrength /MPA                ≥

10.0

——

——

10.0

——


5.

Elongation at maximum force / %      ≥    

——

——

15

——

——


6.

Thermal dimensional change %        ≤

2.0

1.0

0.5

0.1

0.1


7.

Cold bending

-25℃cracks


8.

watertightness

0.3MPA, 2h impervious


9.

Shock resistance

0.kg·m,watertight


10.

Anti static load a

——

——

20kg watertight


11.

Peel strength seams /(N/mm)        ≥

4.0 Or membrane damage

3.0


12.

right angle tear strength /(N/mm)      ≥

50

——

 ——

50

——


 13.

Trapezoidal Tear Strength /(N/mm)           ≥

——

150

250

——

220


 14.

water absorption (70℃,168 h ) /%    

Soaking      ≤

4.0


After to dry   ≥

-0.40


15.

Thermal aging treatment

Exterior

Bond cracks and holes no blistering


Tensile Strength %     ≥

85

——

——

85

——


Breaking elongation rate
%            ≥

80

80

——

80

80


Time / h

 672

Maximum tension retention%   ≥

——

85

85

——

85


Maximum tensile elongation rate %   ≥

——

——

80

——

——


Cold bending

-25 ℃ no crack


16.

chemicalresistance

Exterior

Bond cracks and holes no blistering


Tensile Strength %     ≥

85

——

——

85

——


Breaking elongation rate
%            ≥

80

80

——

80

80


Maximum tension retention%   ≥

——

85

85

——

85


Maximum tensile elongation rate %   ≥

——

——

80

——

——


Cold bending

-25 ℃ no crack


17.

Artificial Weathering c

Exterior

Bond cracks and holes no blistering


Tensile Strength %     ≥

85

——

——

85

——


Breaking elongation rate
%            ≥

80

80

——

80

80


Time / h

1500 b

Maximum tension retention%   ≥

——

85

85

——

85


Maximum tensile elongation rate %   ≥

——

——

80

——

——


Cold bending

-25 ℃ no crack




Note:

a Anti static load only for roofing coiled material requirements.
b  single-layer coil roofing products Artificial Weathering time is 2500 h
C Non exposed roofing membrane does not require the measurement Artificial Weathering






Feature

Roofing membrane PVC waterproof membrane for flat roof
1. Long service life and weathering resistance; and the materials can be used for 30 years on the roof and 50 years underground.  
2. High tensile strength, great elongation, and small size change during heat treatment.
3. Good low temperature flexibility and adaptability to environmental temperature changes.
Good resistance to root penetration. It can be made for green roofs.Excellent resistance to puncture and impact.
4. Convenient for construction (can be welded), solid and reliable, and Eco-friendly.
5. Strong resistance to chemical corrosion, suitable for special occasions.
6. Good plasticity, convenient and quick corner detail treatment. Easy maintenance and low cost. After 2,000 hours of manual weathering verification.  

Note:
Due to unique product formulation, the product has the longer life far beyond the usual waterproof material.
The entire water system is over 30 years on the roof and 50 years underground. It is widely used in construction and civil engineering.


Construction
1.Clean the primary surface debris, debris. Base Paving screed is primary waterproofing membrane, waterproofing
membrane to provide a smooth, dense, there is strength to the bonded structure grassroots
2.The PVC waterproofing membrane by elastic line control position arranged on the base.
3.Find the best position of membrane on base, then lets Membrane keep straight, without distorting, lap width of 120mm,and appropriate cut.
4.Use PVC Glue(brush about 1mm) on the clear base and full sticky, then Paving the membrane on the glue, and planish.
5.Overlapping side edges need use welding machine to weld them together.